Encountering a malfunctioning Maytag Neptune dryer control panel can be frustrating as it hampers your ability to adjust settings or start the dryer. The control panel might exhibit various issues such as lack of power, a blank display, unresponsiveness, or freezing, which can significantly impact the dryer’s functionality.

Maytag Neptune Dryer: Common Issues with Maytag Neptune Dryer Control Panel

  • No Power to Control Panel:
    • Possible Causes:
      • Faulty power supply components like the power cord, fuse, outlet, or tripped breaker.
      • Defective control panel or main control board.
    • Solutions:
      • Ensure the power cord is properly connected and test it for continuity with a multimeter.
      • Check and replace the fuse, if necessary, and assess the circuit breaker.
      • Seek professional assistance to diagnose and replace the control panel or main control board.
    • Maytag Neptune Dryer:Blank Control Panel Display
      • Probable Cause:
        • Faulty control board.
      • Solutions:
        • Attempt a reset and clean the control panel contacts before considering control board replacement.
  • Control Panel Non-Responsiveness with Active Dryer Lights:
    • Possible Causes:
      • Issues with the fuse, start button, door switch, drive belt, timer, or control board.
    • Solutions:
      • Replace components lacking continuity or showing signs of malfunction.
    • Maytag Neptune Dryer:Blank Control Panel Display
      • Probable Cause:
        • Faulty control board.
      • Solutions:
        • Attempt a reset and clean the control panel contacts before considering control board replacement.
    • Unresponsive Control Panel:
  • Frozen Control Panel:
    • Potential Causes:
      • Issues may arise due to a malfunctioning door switch, control panel, or main control board.
    • Solution:
  • Maytag Neptune Dryer: Blank Control Panel Display
    • Probable Cause:
      • Faulty control board.
    • Solutions:
      • Attempt a reset and clean the control panel contacts before considering control board replacement.

Replacement of Maytag Neptune Dryer Control Panel and Control Board:

Replacement of Maytag Neptune Dryer Control Panel and Control Board:

Supplies Needed:

  • Screwdriver
  • New control panel
  • New control board

Steps for Replacement:

  • Power off and disconnect the dryer to ensure safety.
  • Remove the dryer’s top section to access the control panel.
  • Remove the faulty control panel or main control board.
  • Install the new control panel or control board accordingly.
  • Reassemble the dryer and plug it in.
  • Power on the dryer and test the control panel’s functionality.
Steps for Replacement:

FAQs About Maytag Neptune Dryer Control Panel:

  • Reasons for Maytag Neptune Dryer Not Turning On:
    • Lack of power due to various issues such as a tripped breaker, faulty cord, power button, door switch, unresponsive control panel, Control Lock, or incorrect dryer settings.
  • Presence of Fuse in a Maytag Neptune Dryer:
    • Yes, a fuse is located in the blower housing of a Maytag Neptune dryer to safeguard against electrical faults.
  • Resetting Maytag Dryer’s Control Panel:
    • Reset the control panel by unplugging the dryer for 5-10 minutes, flipping the breaker off, or pressing the reset button on the control panel if available.(1)